a wide-range power supply design can meet the demand of 220V± 15% adaptive power supply.
Handle whether to connect detection function, prevent no handle high pressure output, resulting in danger!
Multi-function integration, integrated design: High-power charging power supply + high-power output control unit+ System inspection and control + Serial port screen + software serial port upgrade function.
Create a high-current plugger, safer and more convenient to use.
Multiple protection functions, the whole machine is more reliable.
Multiple fault alarm is convenient and practical.
Unique design, strong output, excellent experience.
Fault problem location and troubleshooting can be solved easily.
A novel technology and modular design are adopted to ensure high efficiency, stability, resistance to vibration and turbulence, and applicability For long distance transportation.
Main features of the product
A wide-variety electricity deliver design can meet the demand of 220v± 15% adaptive strength supply.
Take care of whether to connect detection characteristic, save you no take care of excessive pressure output, ensuing in hazard!
Multi-characteristic integration, integrated design: high-electricity charging power deliver + high-strength output manage unit+ gadget inspection and manipulate + serial port display + software serial port upgrade function.
Create a excessive-cutting-edge plugger, more secure and extra handy to apply.
A couple of protection capabilities, the entire device is greater reliable.
More than one fault alarm is handy and practical.
The power supply parameters
The power supply parameters | |
The input voltage | 220V±15% |
Leakage current | < 0.4mA/250AC |
The output power | 10W—500W (LNIR500-*) |
10W— 1000W (LNIR1000-*) | |
The temperature | Working: -15℃ - +45℃ |
humidity | No frost, no condensation |
Safety and electromagnetic compatibility | It conforms to the standards of medical electrical equipment YY0505-2012 and IEC6061-1-2 |
Cooling way | Forced air cooling |
To protect the | Overload, overvoltage and overcurrent protection |
Auxiliary function | Refrigeration control |
Installation size
The power supply parameters | |
The input voltage | 220V±15% |
Leakage current | < 0.4mA/250AC |
The output power | 10W—500W (LNIR500-*) |
10W— 1000W (LNIR1000-*) | |
The temperature | Working: -15℃ - +45℃ |
humidity | No frost, no condensation |
Safety and electromagnetic compatibility | It conforms to the standards of medical electrical equipment YY0505-2012 and IEC6061-1-2 |
Cooling way | Forced air cooling |
To protect the | Overload, overvoltage and overcurrent protection |
Auxiliary function | Refrigeration control |