AC plasma incinerator power supply

  • High frequency AC high voltage output greatly extends the plasma generator electrode life

  • Special resonant circuit pure high frequency switching conversion, high efficiency, small volume and light weight.

  • Power closed-loop control, the arc work is stable.

  • No-load output voltage, high success rate of arc ignition

  • With the output overvoltage, short circuit, overload protection, the power supply operation is stable and reliable

  • With 0-5V power setting, output current 0-5V transform output, TTL switch control.

  • RS232 interface, for external computer control.

  • The circuit adopts modular design, convenient debugging and maintenance.

  Contact Now
Product Details

Main features


1664519464408813.jpg

Excessive frequency ac excessive voltage output substantially extends the plasma generator electrode lifestyles

Special resonant circuit pure high frequency switching conversion, high efficiency, small volume and light weight.

Power closed-loop control, the arc work is stable.

No-load output voltage, high success rate of arc ignition

With the output overvoltage, short circuit, overload protection, the power supply operation is stable and reliable

With 0-5V power setting, output current 0-5V transform output, TTL switch control.

RS232 interface, for external computer control.

The circuit adopts modular design, convenient debugging and maintenance.





Application area

Applied in gas treatment, lampblack purification, waste gas purification and other fields.


Product Parameter


product model

PDP5000-5000

LSP10000-5000

input voltage range

AC320V-440V, 50 / 60Hz, three-phase

maximum output voltage

AC5000V

Output working current

5A

10A

output frequency

100KHz

The success rate of ignition

More than 99.9%

output power

5KW

10KW

overall efficiency

More than 93%

control interface

The 0-5V power setting, the output current is 0-5V transform output, TTL switch control, and RS232 communication interface

defencive function

Output overvoltage protection, short-circuit protection, overload protection

temperature

Operating temperature: -10-45℃; storage temperature: -20-65℃

humidity

Work: 20-90%RH, no condensation, no storage: 10-95%RH, no condensation

insulation

Pressure resistance: 3000Vac 10mA 60S, insulation resistance: 10M Ω

Safety regulations and electromagnetic compatibility

Meet the relevant industry standards

volume

L×W×H(mm)

315*305*167

315*305*335

weight (Kg)

11.5

23

cooling-down method

forced air cooling



Installation size

1664519614673881.png

1664519614298776.png

                                     PDP10000-5000                                                                   PDP5000-5000