Laser cutting machine equipment common faults and solutions
Laser cutting machine equipment common faults and solutions
1, boot without any response
▶ Power fuse is burnt out: Replace the fuse.
▶ Power input is normal: Check power input and make it normal.
▶ Main power switch is damaged: Replace the main power switch.
2, no laser output or very weak laser
▶ Optical path offset: Carefully adjust the optical path.
▶ Contaminated or damaged reflector lens: Clean or replace reflector lens.
▶ Whether the focal length of the device is changed: readjust the focal length.
▶ Focusing mirror is contaminated: Clean the focusing mirror.
▶ Cooling water quality or temperature is normal: replace the clean cooling water to the normal temperature.
▶ Circulation of cooling water: dredge the cooling water channel.
▶ Laser tube is damaged or aged: Replace the laser tube.
▶ Whether the laser power supply is powered on: check the power supply loop of the laser power supply to make it normal.
▶ Whether the machine temperature is too high:
1. Turn off the machine to make the temperature drop down; 2. Ventilation to enhance the heat dissipation of the machine; 3. Adjust the ambient temperature.
▶ Laser power supply is damaged: Replace the laser power supply.
3, cutting/engraving depth is not ideal
▶ Whether the cutting/engraving machining parameters are normal: Set the appropriate machining parameters.
▶ Laser Power setting is normal: Set the laser power correctly.
▶ Laser output weakening: see point 2.
4. The computer is not connected to the device
▶ Scan switch on: Turn on the scan switch.
▶ Power on motion system: Check the power supply of motion system and make it normal.
▶DSP motion control card is damaged: Replace DSP motion control card.
▶ Signal cable loose: Plug the signal cable and fix it.
5, processing size error or action error
▶ Whether the whole machine and computer are properly grounded: the equipment and computer are well grounded.
▶ Signal cable is normal: Replace the signal cable.
▶ Computer operating system failure or virus infection: Reinstall operating system or remove virus.
▶ Whether your computer is running properly: Replace or dispose of your computer.
▶ Unstable power supply or interference signal: install voltage regulator or eliminate interference signal.
▶ Application Software is Normal: Reinstall the software and motion control card driver software.
▶ Correct setting of processing parameters (such as layout) : Reset the corresponding parameters
▶ Whether the processing program is normal: Check the processing program written and modify it until it is normal.
6, the slider movement is not ideal
▶ Dolly slide and slider is contaminated: Clean slide and slider.
▶ Whether guide rail is polluted: Clean guide rail and add lubricating oil.
▶ Whether the transmission gear is loose: tighten the transmission gear
▶ Whether the transmission belt is loose: adjust the belt tightness.
Recommended Products
W/WA series CO2 laser power supply
1, good adaptation: with active PFC function, to achieve higher power factor, meet the global universal input voltage range AC90-250V,50/60Hz.
2. Upgrade and replace products of general laser power supply: effectively resist the influence of large changes in grid voltage on output current.
3, WA series:
(1) with liquid crystal display: digital display current size, light indication, light signal, water protection signal can indicate the signal normal and fault, integrated potentiometer can manually adjust the current.
(2) The mounting hole size is the same: the LCD screen and the original pointer ammeter opening size is the same, do not need to open a separate hole.
4, good compatibility: can match the vast majority of domestic and foreign 80W-200W CO2 laser;
5, laser equipment high safety factor: with open circuit protection function, significantly improve the life of the power supply;
6, laser power control is simple: 0~5V analog signal control, also available 5V PWM signal control.
7, cutting and carving general purpose: cutting machine speed, power enough, engraving response speed is fast, the bottom surface is smooth;
8, the power supply itself with manual light test function, easy to maintain.
9. With the status indicator, it is easier to judge the status.